7 3/8-10K Coil Cutting Valves

Based on gate valve technology to cut and seal coil tubing, this CCV is equipped with horizontal hydraulically actuated single gate made to shear and seal coiled tubing and wire line of a given specification in the wellbore. A seal is made after the shearing, isolating the pressure/fluids from both upstream and downstream. The coil cutting valve is powered by accumulators and can be overridden via ROV manual over-ride.

Industry Standards

NAME DESCRIPTION REV
API 6A /
ISO 10423
Specification for Wellhead and Christmas Tree Equipment (Latest Edition) 20th Edition October 2010
API 17D /
ISO 13628-4
Specification for Subsea Wellhead & Christmas Tree Equipment (Latest Edition) 2nd  Edition May 2011
API 17G /
ISO 13628-7
Petroleum and natural gas industries- Design and operation of Subsea production systems-part 7: Completion / work over riser system 2nd  Edition July 2006
SAE AS4059Aerospace Fluid Power – Cleanliness Classification for Hydraulic Fluid (Latest Edition) AS4059F September 2013
NACE
MR0175 /
ISO 15156
Petroleum and natural gas industries- Materials for use in H2S-containing environments in oil and gas production 2nd  Edition July 2006
DNVGL-OS-E101Offshore standards, Drilling facilities January 2018

Operating Specification

Pressure / Loading Criteria Specification
Maximum working pressure 10,000 Psi
Maximum Test pressure 15,000 Psi
Temperature / Design Criteria Specification
Temperature Rating P+U
Min. Design Temperature -20° F
Max. Design Temperature 250° F
Nominal bore size 7 3/8”
Drift Dia 7.345 +.027/-.000
Shear Class Coil Tubing and Wire line
Material Class EE-NL (or) Customer Requirement
PSL Level PSL-3G
PR Level 2
Operating Criteria Specification
Water depth 10,000 FT
Service Condition H2S per NACE MR 01-75
ROV override turns to Close 60-62 turns to Clock-wise
Torque to operate override 1900 ft-lbs
Torque Bucket Class 5 (2.0” sq)
API Monogram No
ROV Override Open to Close only
Stroke 9.75”

NOTE: ROV MOR is not capable of shearing tubular

Hydraulic Data

Control Fluid Type HW443 (or) Water based Glycol
Control Fluid Cleanliness SAE AS4059 CLASS 6B-6F
Max. Hydraulic Working Pressure 3,000 psi
Max. Hydraulic Test Pressure 4,500 psi
Cylinder Volume Open: 4.04 US GAL per one Actuator  
Close: 4.22 US GAL per one Actuator
Compensator Fluid Type BIOHYDRAN(2.6 US GAL APPROX) per one MOR
Compensator Check valves (cracking pressure) 50 psi
Search our Product Database:
Scroll to Top